new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Nov 16

CT0: Cybersecurity Transformer

General-purpose frontier models are large, expensive to run, and increasingly reluctant to engage with authorised defensive- and offensive-security work. We ask the opposite question: how small can a cybersecurity-specialist transformer be while remaining genuinely useful to a security practitioner? We introduce CT0, a Cybersecurity Transformer architecture, and CT0-Micro, its first incarnation: a compact (~4B-parameter) model built on the open base model, whose backbone is specialised by two-phase on-policy distillation on our Cybersecurity AI (CAI) dataset. CT0 serves two modes from one set of weights: System 1 answers typed security decisions (is this file suspicious, is this request an attack, did the model just refuse) in a single forward pass without generating a token, System 2 is the usual tool-using agent, and a confidence gate spends generation only where the fast path is unsure. Specialisation lifts the agentic path: CT0-Micro solves 21.1% of cybench-subtask against 7.6% for its base, above every open model of comparable footprint and the densest cybersecurity capability per parameter we measured. The fast path is what the architecture buys: CT0-Micro screens eighty files per second for indicators of compromise, catches its own refusals at 96.5% accuracy in 47 ms where the model judging itself reaches 76.5% in 254 ms and misses half of them, flags jailbreak requests at AUROC 0.966 in 8 ms, and, generating only for the facts it is unsure about, extracts vulnerability facts more accurately than either mode alone at a fifth of the generative cost. All of it is built in about 314 RTX PRO 6000 GPU-hours and served from one workstation GPU, with no policy layer between operator and target. Across eighteen benchmarks and use cases run with one checkpoint and head, we report where the design helps, where it does not, and what it still lacks.

  • 1 authors
·
Oct 11

Segmentation of 3D pore space from CT images using curvilinear skeleton: application to numerical simulation of microbial decomposition

Recent advances in 3D X-ray Computed Tomographic (CT) sensors have stimulated research efforts to unveil the extremely complex micro-scale processes that control the activity of soil microorganisms. Voxel-based description (up to hundreds millions voxels) of the pore space can be extracted, from grey level 3D CT scanner images, by means of simple image processing tools. Classical methods for numerical simulation of biological dynamics using mesh of voxels, such as Lattice Boltzmann Model (LBM), are too much time consuming. Thus, the use of more compact and reliable geometrical representations of pore space can drastically decrease the computational cost of the simulations. Several recent works propose basic analytic volume primitives (e.g. spheres, generalized cylinders, ellipsoids) to define a piece-wise approximation of pore space for numerical simulation of draining, diffusion and microbial decomposition. Such approaches work well but the drawback is that it generates approximation errors. In the present work, we study another alternative where pore space is described by means of geometrically relevant connected subsets of voxels (regions) computed from the curvilinear skeleton. Indeed, many works use the curvilinear skeleton (3D medial axis) for analyzing and partitioning 3D shapes within various domains (medicine, material sciences, petroleum engineering, etc.) but only a few ones in soil sciences. Within the context of soil sciences, most studies dealing with 3D medial axis focus on the determination of pore throats. Here, we segment pore space using curvilinear skeleton in order to achieve numerical simulation of microbial decomposition (including diffusion processes). We validate simulation outputs by comparison with other methods using different pore space geometrical representations (balls, voxels).

  • 6 authors
·
Sep 4, 2023

OmniCT: Towards a Unified Slice-Volume LVLM for Comprehensive CT Analysis

Computed Tomography (CT) is one of the most widely used and diagnostically information-dense imaging modalities, covering critical organs such as the heart, lungs, liver, and colon. Clinical interpretation relies on both slice-driven local features (e.g., sub-centimeter nodules, lesion boundaries) and volume-driven spatial representations (e.g., tumor infiltration, inter-organ anatomical relations). However, existing Large Vision-Language Models (LVLMs) remain fragmented in CT slice versus volumetric understanding: slice-driven LVLMs show strong generalization but lack cross-slice spatial consistency, while volume-driven LVLMs explicitly capture volumetric semantics but suffer from coarse granularity and poor compatibility with slice inputs. The absence of a unified modeling paradigm constitutes a major bottleneck for the clinical translation of medical LVLMs. We present OmniCT, a powerful unified slice-volume LVLM for CT scenarios, which makes three contributions: (i) Spatial Consistency Enhancement (SCE): volumetric slice composition combined with tri-axial positional embedding that introduces volumetric consistency, and an MoE hybrid projection enables efficient slice-volume adaptation; (ii) Organ-level Semantic Enhancement (OSE): segmentation and ROI localization explicitly align anatomical regions, emphasizing lesion- and organ-level semantics; (iii) MedEval-CT: the largest slice-volume CT dataset and hybrid benchmark integrates comprehensive metrics for unified evaluation. OmniCT consistently outperforms existing methods with a substantial margin across diverse clinical tasks and satisfies both micro-level detail sensitivity and macro-level spatial reasoning. More importantly, it establishes a new paradigm for cross-modal medical imaging understanding. Our project is available at https://github.com/ZJU4HealthCare/OmniCT.

  • 15 authors
·
Feb 17

ARC-CT: Anatomy-Routed Contrastive Vision-Language Learning for 3D Chest CT

Contrastive vision-language learning uses paired chest CT volumes and radiology reports to learn abnormality classifiers without manually annotated labels. However, two characteristics of chest CT challenge conventional global contrastive learning. First, many critical abnormalities are small or anatomically localized, and pooling an en- tire volume into a single embedding may dilute their visual evidence. Second, the standard contrastive objective treats every other scan in a batch as a negative. Because many chest CTs share abnormalities, this objective incorrectly pushes co-positive pairs apart. We propose Anatomy-Routed Contrastive Learning for 3D Chest CT (ARC-CT), a region-aware framework that addresses these limitations using only la- bels extracted from reports by an LLM, with no manual annotations or bounding boxes. ARC-CT combines three components: (1) an Anato- myQFormer localizing evidence via queries constrained by automatically generated organ masks; (2) a label-Jaccard soft InfoNCE objective in- tegrating the standard one-hot target with the label-set overlap of each pair, which reduces false-negative penalties between studies that share clinical findings; and (3) an organ-level alignment loss connecting mask- pooled visual features to organ-specific report text extracted offline with a large language model. ARC-CT achieves a 0.86 mask-free macro AUC across 18 abnormalities using a compact 3D ResNet-18 backbone. Over- all, ARC-CT outperforms both comparable efficient baselines and sev- eral larger transformer models. Our code and weights are available at https://github.com/arc-ct/arc-ct.

  • 4 authors
·
Aug 27

NV-Reason-CT: 3D Visual Language Model for CT Analysis

We present NV-Reason-CT, a generative vision--language model for chest and abdominal CT combining native 3D visual encoding with radiologist-guided reasoning. The model couples a native 3D vision transformer with a language model, passing all visual tokens and their explicit 3D coordinates into language decoding without further spatial token merging. This retains volumetric spatial information within the vision encoder and through the language model's positional encoding during joint processing with text. We train on a curated corpus of approximately 550,000 multimodal instruction examples from 70,111 unique CT image inputs, combining standardized reports, abnormality-focused and anatomy-specific questions, multi-turn interactions, and radiologist-authored reasoning from recorded and transcribed expert CT interpretations. Expert annotations provide direct supervision and guide additional report-grounded synthetic reasoning. End-to-end supervised fine-tuning (SFT) is followed by Group Relative Policy Optimization (GRPO), with verifiable rewards over chest and abdominal abnormality sets. The model supports abnormality classification, report generation, and interactive reasoning with reviewable observations, differential diagnoses, and uncertainty. Evaluation spans public CT benchmarks and a held-out NIH cohort. On CT-RATE, NV-Reason-CT achieves a macro-F1 of 0.614 and macro-AUROC of 0.871 without a task-specific classification head; generated reports achieve a report-derived macro-F1 of 0.592. In a preliminary study with expert radiologists, AI-assisted review received favorable confidence ratings and was associated with a 50% reduction in average reported interpretation and reporting time. We release the model and training code to support reproducible research on explainable AI for volumetric medical imaging.

  • 16 authors
·
Sep 22

Curriculum-Driven 3D CT Report Generation via Language-Free Visual Grafting and Zone-Constrained Compression

Automated radiology report generation from 3D computed tomography (CT) volumes is challenging due to extreme sequence lengths, severe class imbalance, and the tendency of large language models (LLMs) to ignore visual tokens in favor of linguistic priors. We present Ker-VLJEPA-3B, a four-phase curriculum learning framework for free-text report generation from thoracic CT volumes. A phased training curriculum progressively adapts a Llama 3.2 3B decoder to ground its output in visual features from a frozen, self-supervised encoder. Our visual backbone (LeJEPA ViT-Large) is trained via self-supervised joint-embedding prediction on unlabeled CTs, without text supervision. Unlike contrastive models (CLIP, BiomedCLIP), this language-free backbone yields modality-pure representations. Vision-language alignment is deferred to the curriculum's bridge and generation phases. This modality-agnostic design can integrate any self-supervised encoder into an LLM without paired text during foundation training. Methodological innovations include: (1) zone-constrained cross-attention compressing slice embeddings into 32 spatially-grounded visual tokens; (2) PCA whitening of anisotropic LLM embeddings; (3) a positive-findings-only strategy eliminating posterior collapse; (4) warm bridge initialization transferring projection weights; and (5) selective cross-attention freezing with elastic weight consolidation to prevent catastrophic forgetting. Evaluated on the CT-RATE benchmark (2,984 validation volumes, 18 classes), Ker-VLJEPA-3B achieves a macro F1 of 0.429, surpassing the state-of-the-art (U-VLM, macro F1 = 0.414) by 3.6%, and reaching 0.448 (+8.2%) with threshold optimization. Ablation studies confirm 56.6% of generation quality derives from patient-specific visual content. Code and weights are available.

  • 4 authors
·
Mar 24

Large Language Model-Assisted Cleaning of Report-Derived Labels in a Large-Scale Chest CT Dataset

Purpose: To evaluate whether large language model (LLM)-assisted label cleaning can identify label-report discordance in CT-RATE, a large-scale public chest CT dataset. Materials and Methods: After report-level deduplication, 24,446 unique radiology reports were identified. Twelve reports were excluded from the primary GPT-5.4 analysis because of Microsoft Azure AI Foundry content-safety filtering, leaving 24,434 reports and 439,812 label instances across 18 abnormality categories. GPT-5.4-derived binary labels were generated from report text using structured JSON output and compared with existing CT-RATE labels. Discordant instances were adjudicated by radiologists. In addition, 100 randomly sampled reports were manually annotated to compare CT-RATE labels, individual LLM-derived labels, and multi-LLM majority-vote labels against radiologist-annotated reference labels. Results: Overall agreement between GPT-5.4-derived and CT-RATE labels was 96.4%, with Cohen's kappa of 0.884. Lymphadenopathy showed the lowest agreement and kappa. In discordance review, radiologist adjudication supported GPT-5.4-derived labels in 72 of 97 (74.2%) general discordant instances and 91 of 99 (91.9%) targeted lymphadenopathy discordant instances. Against radiologist-annotated reference labels, multi-LLM majority-vote labels achieved the highest label-macro-averaged F1 score and Cohen's kappa. Conclusion: LLM-assisted label cleaning identified clinically meaningful label-report discordance in CT-RATE and may support scalable quality improvement of public imaging datasets. The cleaned dataset will be made publicly available to support future research.

  • 7 authors
·
Jun 20

Resolution Meets Reduction: Efficient Visual Context for 3D Radiology Report Generation

Vision-language models offer a promising path toward automating radiology report generation, but applying them to full 3D CT volumes poses substantial computational challenges. Modern foundation vision encoders (VEs) can produce tens of thousands of vision tokens per scan, making the visual sequence passed to the large language model (LLM) a primary computational bottleneck. Vision-to-language projectors can compress this sequence to reduce computation, but may discard clinically relevant detail; conversely, effective compression can accommodate higher-resolution inputs while keeping the downstream token count fixed. How this vision-token budget should be allocated across input field of view, spatial resolution, and vision-to-language projection therefore remains an open design question. We systematically evaluate four heterogeneous VEs (CNN- and ViT-based), five token-reducing projectors at up to 64x compression alongside a non-reducing MLP projector baseline, and five instruction-tuned LLMs (1.7B--4B) on two large-scale CT report datasets (CT-RATE and Merlin). At matched LLM token budgets, anatomy-guided region of interest cropping is the most consistent strategy, improving clinical macro F1 in 19 of 20 settings by +3.7 points on average for the 3D ViT Primus encoder and +1.1 for the slice-based 2D ViT Curia encoder. Increasing input resolution further is strongly projector-dependent: the PerceiverResampler, paired with higher-resolution Curia features, yields the strongest configuration in the resolution study on both datasets. Our best configurations achieve state-of-the-art clinical macro F1 on the test sets, reaching 49.5 on CT-RATE and 49.0 on Merlin. Code and models will be published upon publication.

  • 13 authors
·
Aug 8